LYST
Applications
LYST airport cables are used for connection between control tower and constant current regulators (CCRs), suitable for transmission of voice data up to 2,000 kHz.
Standards
NF C 32 070 C2
Construction
Conductor | Solid bare copper. |
Insulation | PE |
Cable Element | Pairs |
Separator | One or more plastic tapes. |
Shield | Polyester-aluminium tape with drain wire. |
Sheath | PVC. |
Technical Data
Rated Voltage Uo/U (Um) | 200V |
Maximum Conductor Temperature | 90°C |
Short Circuit Temperature | 250°C |
Operating Temperatures | -15°C~+70°C |
Minimum Bending Radius | static: 6×OD; dynamic: 12×OD |
Lead Free | Yes |
Dimensions and Weight
Construction | AWG | Nominal Overall Diameter | Nominal Weight |
---|---|---|---|
No. ×mm² | - | mm | kg/km |
1×2×0.20 | 24 | 3.6 | 18 |
2×2×0.20 | 24 | 4.5 | 27 |
3×2×0.20 | 24 | 5.0 | 33 |
5×2×0.20 | 24 | 6.0 | 47 |
10×2×0.20 | 24 | 7.2 | 77 |
15×2×0.20 | 24 | 8.2 | 104 |
30×2×0.20 | 24 | 11.0 | 193 |
56×2×0.20 | 24 | 14.7 | 334 |
112×2×0.20 | 24 | 19.5 | 626 |
1×2×0.50 | 20 | 4.8 | 31 |
2×2×0.50 | 20 | 7.0 | 57 |
3×2×0.50 | 20 | 7.2 | 70 |
5×2×0.50 | 20 | 8.6 | 97 |
10×2×0.50 | 20 | 11.3 | 174 |
15×2×0.50 | 20 | 12.9 | 236 |
30×2×0.50 | 20 | 16.8 | 441 |
56×2×0.50 | 20 | 23.4 | 799 |