• Home
  • About Caledonian
  • Products
  • Applications
  • Technical Information
  • Download
  • Sitemap Testing Authorities | Testing Equipment Manufacturers | Magazines | Organizations | Caledonian Corporater Website
  • Contacts

Caledonian Airport Cables

  • Airport Lighting Power Cables
  • Airport Series Runway Lighting Cables
  • Airport Lighting Fire Resistant Cables
  • Airport Lighting Flame Retardant Cables
  • FAS (Fire Alarm System)

  • Detector Cable
  • Fire Communication Cable
  • Sounder Cable
  • Control Cable
  • RS485 Data Cable

SACS (Security Access Control System)

  • RS485 Data Cables
  • Push Button Cables
  • Lock Cables
  • Card Reader Cables

CCTV (Closed Circuit TV)

  • Video Cables
  • RS485 Data Cables

PAS (Public Address System)

  • Loudspeaker Cables
  • RS485 Data Cables

BMS (Building Management System)

  • Digital Signal Cables
  • Analog Signal Cables
  • RS485 Data Cables
  • Temperature Control Cables

CPMS (Car Park Management System)

  • Communication Cables
  • Talk-back Cables

Baggage Handling System Cables

Flame Retardant Data Cables

Flame Retardant CAT5e CWB/SWB/SWA Armoured Data Cables

FGD-CAT5e U/UTP4P24 cwb/swb/swa FGD-CAT5e f/UTP4P24 cwb/swb/swa FGD-CAT5e sf/FTP4P24 cwb/swb/swa

Flame Retardant Data Cables

APPLICATION

Cat5E is a cable standard for Gigabit Etdernet and otder network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, tdese cables can be offered witd copper wire braid armoured & flame retardant outer sheatd, providing additional mechanically protection still maintaining tde flexibility of tde cable.

STANDARDS

Basic design adapted to EN50173

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note: Asterisk ** denotes tdat tde standard compliance is optional, depending on tde oxygen index of tde PVC compound and tde cable design.

VOLTAGE RATING

60V

CABLE CONSTRUCTION

Conductors: 24AWG solid bare copper.
Insulation: HDPE.
Twinning: Two coloured insulated conductors twisted togetder to form a pair. Inner Sheatd: Flame retardant, low smoke and halogen-free polyolefin, coloured black
Armouring: cwb: copper Wire Braid swb: Steel Wire Braid swa: Steel Wire Armour
Outer Sheatd: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on tde oxygen index of tde PVC compound and tde overall cable design. LSPVC can also be provided upon request.
Cat5E F/UTP: These cables have collective shielding of aluminium/Polyester tape witd drain wire.
Cat5E SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid.

Physical AND THERMAL PROPERTIES

Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter

Electrical Properties

AWG   24
Nominal Conductor Diameter mm 0.5/0.53
Maximum DC Resistant@20°C Ω/100m 9.38
Maximum DCR Unbalance % 5
Maximum Mutual Capacitance pF/m 55.8
Maximum Capacitance Unbalance pF/100m 330
Characteristic Impedance@1-100MHz Ω 100+/-15
Maximum Propagation Delay Skew ns/100m 45

Transmission Properties

FREQ MHz Maximum Attenuation dB/100m Minimum NEXT dB Minimum PSNEXT dB Minimum ELFEXT dB/100m Minimum PSELFEXT dB/100m Minimum RL dB
0.772 1.8 67.0 64.0 66.0 63.0 —
1 2.0 65.3 62.3 63.8 60.8 20.0
4 4.1 56.3 53.3 51.7 48.7 23.0
8 5.8 51.8 48.8 45.7 42.7 24.5
10 6.5 50.3 47.3 43.8 40.8 25.0
16 8.2 47.3 44.3 39.7 36.7 25.0
20 9.3 45.8 42.8 37.7 34.7 25.0
25 10.4 44.3 41.3 35.8 32.8 24.3
31.25 11.7 42.9 39.9 33.9 30.9 23.6
62.5 17.0 38.4 35.4 27.8 24.8 21.5
100 22.0 35.3 32.3 23.8 20.8 20.1

FGD Cat5E SF/UTP

FGD Cat5E SF/UTP

CONSTRUCTION PARAMETERS

Cable Code Construction
No. of elements×
No. of cores in
element×
Conductor
diameter
Nominal Insulation Thickness Nominal
Inner
Sheatd Thickness
Nominal
Outer
Sheatd Thickness
Nominal Overall Diameter Nominal Weight
  mm mm mm mm mm kg/km
FGD-CAT5E U/UTP CWB 4×2×0.5 0.2 0.6 1.0 7.68 97
FGD-CAT5E U/UTP SWB 4×2×0.5 0.2 0.6 1.0 7.68 93
FGD-CAT5E U/UTP SWA 4×2×0.5 0.2 0.6 1.0 8.68 165
FGD-CAT5E F/UTP CWB 4×2×0.53 0.2 0.6 1.0 8.28 116
FGD-CAT5E F/UTP SWB 4×2×0.53 0.2 0.6 1.0 8.28 112
FGD-CAT5E F/UTP SWA 4×2×0.53 0.2 0.6 1.0 9.28 192
FGD-CAT5E SF/UTP CWB 4×2×0.53 0.2 0.6 1.0 8.76 123
FGD-CAT5E SF/UTP SWB 4×2×0.53 0.2 0.6 1.0 8.76 119
FGD-CAT5E SF/UTP SWA 4×2×0.53 0.2 0.6 1.0 9.76 216