FLGCG Runway Cables
Applications
FLGCG cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constant Current Regulators and the isolating transformers, and between the isolating transformers.
Standards
C33-224
C33-225
Construction
Conductor: Stranded bare or tinned copper conductor.
Inner Semi-Conductor: Extruded semi-conducting compound.
Insulation: XLPE. EPDM可选
Outer Semi-Conductor: Extruded semi-conducting compound.
Shield: Copper tape shield. 铜丝屏蔽可选
Sheath: XLPE. PVC/HFFR/CR可选
Technical Data
Rated Voltage Uo/U (Um) | 3.6/6(7.2kV); 6/10 (12kV) |
Maximum Conductor Temperature | 90℃ |
Short Circuit Temperature | 250℃ |
Operating Temperatures | -20℃~+70℃ |
Minimum Bending Radius | static: 10×OD; dynamic: 20×OD |
Impacted Resistant | Yes |
Weather Resistant | Yes |
Dimensions and Weight
3.6/6 (7.2kV)
Construction | No. of Strand | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight |
---|---|---|---|---|---|
No. ×mm² | - | mm | mm | mm | kg/km |
1×6 | 7 | 2.7 | 1.4 | 12.5 | 198 |
6/10 (12kV)
Construction | No. of Strand | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight |
---|---|---|---|---|---|
No. ×mm² | - | mm | mm | mm | kg/km |
1×6 | 7 | 3.6 | 1.6 | 14.7 | 250 |